Valvola a solenoide 142228 NC Burkert, 10 bar max, 2 porte, 24V cc

Immagine rappresentativa della gamma

Al momento non disponibile
Non sappiamo se questo articolo tornerà in stock, RS intende rimuoverlo a breve dall'assortimento.
Codice RS:
388-5034
Codice costruttore:
142228
Costruttore:
Burkert
Trova prodotti simili selezionando uno o più attributi.
Seleziona tutto

Marchio

Burkert

Tipo prodotto

Valvola a solenoide

Posizione predefinita della valvola

NC

Pressione operativa massima

10 bar

Numero di porte

2

Tensione di alimentazione

24 V cc

Applicazione

Sostanza neutra

Materiale corpo

Poliammide

Fattore di flusso (Kv)

1.8 m³/h

Tempo massimo di chiusura

150 ms

Tempo massimo di apertura

30 ms

Temperatura massima di funzionamento

50 °C

Minima temperatura operativa

0 °C

Diametro orifizio

10 mm

Serie

6228

Servomeccanismo

Sì

Paese di origine:
DE

6228 Series 2//2-way Plastic Solenoid Valve


Servo-assisted 2//2-way normally closed solenoid valve

For general purpose applications - including water and sewage treatment, distribution and irrigation systems, dosing, filling and batching

Compact and lightweight

Low power consumption

0.5 to 10 bar pressure range

Servo diaphragm seal: FPM Body in PPE/PA

Unique pipe connection system allows ease of replacement for maintenance applications

Neutral fluids with a maximum temperature of 50°C that will not affect the plastic material e.g. pressurized air, water, hydraulic oils, oils or fat without additives

Ambient temperature 55°C max.

Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3 / 2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2 / 2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.

Note

2 pipe connectors required per valve

Link consigliati

Rimani aggiornato sulle novità di prodotto e sulle nostre offerte!

Indirizzo email